12000 风量油烟净化器 使用说明书 简介 Introduction to the instruction manual of low altitude 12000 air volume soot purifier


SL 系列模块化静电式 低空 12000 风量油烟净化器 ,是本公司根据国家环保总局的有关规定及要求研制生产的,它能有效地清除有害气体,消除异味从而净化作业环境,彻底解决污染转移问题。 Super Blue SL series modular electrostatic low - altitude 12000 air volume soot purifier was developed by our company in accordance with the relevant regulations and requirements of the State Environmental Protection Administration. It can effectively remove harmful gases, eliminate odors, thereby purify the operating environment, and completely solve the pollution transfer problem.


系列模块化静电式 低空 12000 风量油烟净化器 采用静电吸附原理,所以有很高的去除效率同时还保持较低的能耗。 The SL series modular electrostatic low - altitude 12000 air volume soot purifier uses the principle of electrostatic adsorption, so it has high removal efficiency while maintaining low energy consumption.


速蓝 SL 系列模块化静电式 低空 12000 风量油烟净化器 可以成为饮食业油烟净化及工业生产中去除油烟的强效工具。 Under the correct installation and operating conditions, the Super Blue SL series modular electrostatic low - altitude 12000 air volume soot purifier can become a powerful tool for the soot purification in the catering industry and the removal of soot in industrial production.


This product provides effective technical means for implementing environmental standards.


Second, the principle

系列 低空 12000 风量油烟净化器 为二级式静电吸附型,用来去除细微粒径的碳氢化合物和其它空气中的杂粒。 SL series low altitude 12000 air volume soot purifier is a two-stage electrostatic adsorption type, which is used to remove fine particle size hydrocarbons and other airborne particles. Its two-stage type refers to the ionization section and the collection section. Each ionization section consists of a series of tungsten steel wires, is installed in the middle of a series of ground plates, and passes high-voltage direct current. Particles in the atmosphere are ionized with a positive or negative charge when they pass through the strong electrostatic field of the ionizer.


Each collection section consists of a large number of parallel plates. High-voltage direct current (the polarity is the same as the ionizer, but the voltage is halved) to form an electric field. The charged particles are attracted by the ground plate and driven by the charged plate. For this reason, when charged particles are contained in the air stream, they can be efficiently removed.


The collecting assembly must ensure the low-speed passage through the collecting section while ensuring a smooth airflow distribution. The air flow is powered by a fan located behind the collection module, which allows the air to flow at a specific speed.


Third, the scope of application

Purification of oil fume in hotels, restaurants and other catering industries; purification of oil fume in canteens of schools, hospitals, industrial and mining enterprises; and treatment of oil fume pollution in food processing plants.


Technical characteristics:

Efficient: Efficiently capture soot particles with different particle sizes, high purification efficiency, and fundamentally solve the problem of pollution transfer.


Flexible: Modular purification units can be flexibly combined, and the number of units can be adaptively adjusted according to different purification treatment volumes and purification efficiency requirements.


Convenient: The modular purification unit adopts a split drawer structure, which is easy to install and maintain, and it is particularly convenient to clean.


Advanced: The electrostatic power control system can automatically adjust the strength of the electric field, so that the purification equipment maintains a high purification rate after long-term operation.


Safety: The security system is well-designed, the maintenance door is opened, and the high-voltage power supply is automatically cut off. The high-voltage power supply is carefully designed as a unit sealed with epoxy resin, which is safe and reliable. It uses flashover tracking technology used by mainframes and can be equipped with The remote control system greatly improves the safety factor of operation.


Stability: The electrostatic power control system has an over-current and over-voltage automatic protection device to ensure the stable operation of the equipment.


Economical: Long service life, high efficiency and energy saving, small footprint.


产品部件说明 Five, product parts description

餐饮油烟净化器

1) (Figure 1)


电气箱门锁 First, electrical box door lock

铭牌 Nameplate

工作电流指示表 Third, the working current indicator

工作电压指示表 Fourth, the working voltage indicator

工作指示灯 Five, work indicator

断电开关 Six, power off switch

餐饮油烟净化器厂家

2 ( Figure 2 )


高压供应器 Seven, high voltage supply

散热风扇 Eight, cooling fan

接线排 Nine, wiring

空气开关 Ten, air switch

高压接线柱 Eleven, high-voltage terminals

抵押接线柱 Twelve, mortgage terminals


深圳餐饮油烟净化器

3 ( Figure 3 )


封边胶条 Thirteen, edge banding tape

电离器 Fourteen, ionizer

高压绝缘子 Fifteen, high-voltage insulators

餐饮油烟净化器

                                                              

(Figure 4)

高压区导电板通电触头 16.Electrical contact of conductive plate of high voltage

低压区导电板通电触头 Seventeen, low-voltage area conductive plate power contacts

搬运提环 Eighteen, lifting ring

风向标志 Nineteen, wind direction signs

安装图示 Six, installation icon

厂家


5) ( Figure 5)


A: Cooker  

B: Smoke collection hood  

C: Elbow  

D: Duct   

E: reducer (smaller to larger)  

F: Purifier

G: reducer (larger and smaller)  

H: Fan   I: cigarette cap

 

餐饮油烟净化器品牌

(Figure 6)

A: Cooker    

B: Smoke collection hood   

C: Elbow   

D: Duct   

E: reducer (smaller to larger)

F: Purifier  

G: reducer (larger and smaller)   

H: Fan   

I: cigarette cap

安装应满足以下条件 7. The installation of catering oil fume purifiers should meet the following conditions

1. The ventilation volume in the purification system should be within the rated processing air volume of the purifier

2. The purifier should be installed at a level, otherwise, the oil collected by the purifier will be sucked out by the fan, or the oil in the purifier cannot be exhausted when the oil is discharged .

3. The wind speed in the pipeline should be designed at 8 ~ 10m / S

4. Elbow centerline radius ≥ 1.5D (if this condition is not met, the wind resistance of the reducer will be doubled)

5. 导流板,否则,净化器净化效率将大幅度降低而不能达到国家排放标准)。 The angle between the hypotenuse and the axis of the reducer (smaller to larger) is ≦ 7 (if this condition is not met, a reasonable installation of a deflector should be considered , otherwise the purification efficiency of the purifier will be greatly reduced and cannot meet the national emission standard). 7(A) 所示 As shown in Figure 7 (A) :

深圳餐饮油烟净化器

7) (Figure 7)


6. The angle between the hypotenuse of the reducer (larger and smaller) and the axis ≦ 15 (if this condition is not met, a reasonable installation of a deflector should be considered, otherwise, the purifier cannot exert its effectiveness). 7(B) 所示; As shown in Figure 7 (B) ;


7. There should be a straight pipe ≥2.5D before the air inlet of the purifier (if this condition is not met, a reasonable installation of the air distribution plate and the deflector should be considered, otherwise, the purifier cannot exert its effectiveness);


8. Fans should be installed with shock absorbers;


9. The air inlet and outlet of the fan shall be installed with a soft connection;


线 接地) 10. The purifier must be reliably grounded (the purifier has 3 outlets, the red and green wires are connected to 220V / AC, and the yellow and green wires are grounded)


Eight, the wind direction

The equipment is set to be left-inlet air before leaving the factory (facing the door of the purifier electrical box, the airflow from left to right is left-inlet air, otherwise it is right-inlet air). 4 所示之电场旋转 180 (第27标识与实际风向一致),将弹簧接头由下方移致上方,再将图2中1 2 1 3 上的电线对换则完成了由左进风调整为右进风之过程。 If the site needs to use the right wind, rotate the electric field 180 as shown in Figure 4 (the 27th mark is consistent with the actual wind direction), move the spring connector from the bottom to the top, and then connect the wires on 1 2 and 1 3 in Figure 2 The change was completed from the left air intake to the right air intake.


Nine, power on debugging

3根出线,红线和绿线接220V/AC,黄绿线接地,接地电阻应小于2欧母。 The purifier has 3 outlets, the red and green wires are connected to 220V / AC, the yellow and green wires are grounded, and the grounding resistance should be less than 2 ohms. 5 7 )红灯亮 1秒后绿灯亮,同时红灯熄灭,有轻微连续平稳的“哧”静电放电声,视为正常工作。 Turn on the power of the purifier. At this time , the red light of the purifier ( 5 , 7 shown in Figure 1 ) lights up for 1 second, the green light turns on, and the red light turns off at the same time. . During the power-on debugging, there are occasional intermittent "squeaking, popping" high-voltage discharge sounds in the purifier. This is normal. If there is a continuous “slap, pop ...” high-voltage discharge sound, this indicates that there are foreign objects in the low-voltage area of the electric field (such as paper scraps for kitchen ignition, and debris left in the newly installed air duct). At that time, the power of the purifier should be turned off, the electric field warehouse door should be opened, and the electric field should be drawn to clear the foreign matter, and the purifier should be restarted after being eliminated. If there is any abnormality, please notify the service station.


使用 Ten, the use of catering fume purifiers

1. 1中的 5 ),红灯不亮(图 1中的 7 ); When the purifier works normally, the electric field emits a slightly continuous and steady “哧” static discharge sound, the green light is on ( 5 in Figure 1 ), and the red light is off ( 7 in Figure 1 );

2. When the purifier is working, there is occasionally a "pop, pop" high-pressure discharge sound, which is normal. The above phenomenon is a display of the automatic detection and elimination process of the fault by the purifier.

3. When the purifier is in use, the green light is on, and the red light is also on, which indicates that the purifier needs to be cleaned. 判别后进入保护状态。 If it is not cleaned, the purifier will automatically identify and enter the protection state.

4. When the purifier is in use, the red light is on and the green light is off, which means that the purifier has entered the automatic protection state and stopped working. After cleaning the electric field, the purifier can enter the normal working state.

5. The purifier should be drained regularly to prevent oil from leaking when the oil collecting pan of the purifier is full.

6. 1~3个月(视使用情况可适当延长或缩短)。 The cleaning cycle of the purifier is 1 to 3 months (it can be appropriately extended or shortened depending on the use).

7. It is strictly forbidden for non-professionals to disassemble, debug, and repair the purifier. In the event of a failure, the power supply shall be turned off in a timely manner for inspection by authorized professional maintenance personnel. The high-voltage electrostatic oil fume purifier circuit system must not be touched during work to avoid high-voltage injuries.


清洗保养 Eleven, low-altitude 12000 air volume catering fume purifier cleaning and maintenance

2 3 个月,在营业时间长、油烟浓度高的地点清洗周期可适当缩短 The electric field unit must be cleaned regularly to avoid affecting the processing efficiency and causing accidents. The cleaning interval in areas with ordinary soot concentration is 2 to 3 months . The cleaning cycle can be appropriately shortened in places with long business hours and high soot concentrations . After confirming that the power is off, open the electric field compartment door and take out each electric field in sequence. (Note: Do not damage the electric field body or any insulation on the box when performing the above operations, or replace it) Parts to be cleaned: high-voltage insulators, electric fields, and guide grooves in the chassis. High-voltage insulator cleaning method: Wipe it with alcohol until it looks clean.


The electric field cleaning method is as follows:

1. Mechanical cleaning

A. The taken electric field body is immersed in an ultrasonic cleaning tank. The cleaning liquid in the tank (605+ metal cleaning agent for the preparation of the cleaning liquid is prepared at a ratio of 1:10, and the water temperature is preferably about 80 ° C). Standard, soaking time is about 30 minutes (the purpose is to facilitate cleaning):

B. Start the ultrasonic cleaner and the cleaning time is 30 minutes. If you find that the cleaning is not completed within 30 minutes, you can extend the cleaning time appropriately.

C. Rinse the cleaned electric field body with clean water, then place it in a ventilated place or air dry in the sun, if necessary, use an electric blower to dry the electric field (the degree of drying is based on the absence of obvious visible water drops on each part).

D. Use a 2500V shake meter to measure the resistance between the positive and negative electrodes. It should be> 50MΩ as normal.


2. 手工清洗 Catering fume purifier manual cleaning

A. 5分钟。 Place the taken out electric field body in a cleaning tank for immersion. The cleaning solution in the tank (the preparation of the cleaning solution is prepared with industrial caustic soda at a ratio of 1:20, and the water temperature is preferably about 60 ° C). The immersion time shall prevail. 5 minutes.

B. Take the electric field body out of the cleaning tank and rinse it with high-pressure water. The dirt must be completely removed during rinsing. Even though the parts look clean, there may still be detergent residue. Residual detergent will attack the aluminum plates and is best rinsed with hot water.

C. Place the cleaned electric field body in a ventilated place or air dry in the sun, use it if necessary

The hair dryer dries the electric field (the degree of drying is based on the absence of visible water droplets in each part).


3. Put the parts back into the purifier box as they are.


4. Do not turn on the power of the purifier when the electric field is not connected to avoid excessive high-load high-voltage breakdown of the insulator and discharge accidents.


常见故障及排除 Twelve, common faults and elimination of low-altitude 12000 air volume catering purifiers

Process

Failure situation

Possible Causes

Check item

Processing method

1

Static electricity cannot be turned on

Leakage breaker action

Visual inspection

maintain

High voltage insulation is damaged or

High voltage generator failure

Measured with a three-purpose checklist

replace

2

Electrostatic machine has continuous flapping sound

Plate too wet

Turn off the fan to blow

20-30 minutes

service

The plates are too dirty

Visual inspection

Clean

Poor grounding

Visual inspection

service

Obstacle damage

Visual inspection

replace

3

Machine debugging

Machine debugging

Turn off other unused appliances

activation

Machine leakage

service

The plates are too dirty

Clean

4

Damaged high-voltage insulated wire

Burned out and cracked insulation

Visual inspection

replace

Damaged high voltage generator

Short circuit

Visual inspection

service

The plates are too dirty

Visual inspection

Clean

High and low pressure joints

Poor contact

Visual inspection

service

5

Poor purification effect

The plates are too dirty

Plate spacing

Clean

Output voltage is too low

High-pressure probe measurement

Adjustment

The wind is too fast

Wind speed measurement

Adjustment


Previous: Low-altitude 8000 air volume soot purifier

Next: Low altitude 16000 air volume soot purifier

Recommended Products

低空20000风量油烟净化器
Low altitude 20000 air volume soot purifier
低空4000风量油烟净化器
Low altitude 4000 air volume soot purifier
低空6000风量油烟净化器
Low altitude 6000 air volume soot purifier
低空8000风量油烟净化器
Low altitude 8000 air volume soot purifier
低空16000风量油烟净化器
Low altitude 16000 air volume soot purifier
低空24000风量油烟净化器
Low altitude 24000 air volume soot purifier

  • Verification code:

    威尼斯人官网 | Products | Strength Display | News Center | Case Center | About Us | Contact Us | Site Map